Reference
The tables that get looked up with cold hands. Everything is a starting point; the last word belongs to the negative.
Long exposures
Past about one second film responds less than the meter promises. The makers of most of the films used here publish one number per film: raise the metered time, in seconds, to that power and expose for the result.
| Film | Power | Metered 30 s | Metered 2 min |
|---|---|---|---|
| Ortho Plus | 1.25 | 1 min 10 s | 6 min 35 s |
| FP4 Plus | 1.26 | 1 min 15 s | 6 min 55 s |
| Delta 100 | 1.26 | 1 min 15 s | 6 min 55 s |
| Kentmere 100 | 1.26 | 1 min 15 s | 6 min 55 s |
| Kentmere 400 | 1.30 | 1 min 25 s | 8 min 25 s |
| HP5 Plus | 1.31 | 1 min 25 s | 8 min 50 s |
| Pan F Plus | 1.33 | 1 min 30 s | 9 min 45 s |
| Delta 3200 | 1.33 | 1 min 30 s | 9 min 45 s |
| Delta 400 | 1.41 | 2 min | 14 min 15 s |
| SFX 200 | 1.43 | 2 min 10 s | 15 min 40 s |
Worked through for four of them:
| Metered | FP4 Plus | HP5 Plus | Pan F Plus | Delta 400 |
|---|---|---|---|---|
| 1 s | 1 s | 1 s | 1 s | 1 s |
| 2 s | 2.4 s | 2.5 s | 2.5 s | 2.7 s |
| 4 s | 5.7 s | 6.1 s | 6.3 s | 7.1 s |
| 8 s | 14 s | 15 s | 16 s | 19 s |
| 15 s | 30 s | 35 s | 37 s | 46 s |
| 30 s | 1 min 15 s | 1 min 25 s | 1 min 30 s | 2 min |
| 1 min | 2 min 55 s | 3 min 35 s | 3 min 50 s | 5 min 20 s |
| 2 min | 6 min 55 s | 8 min 50 s | 9 min 45 s | 14 min 15 s |
| 4 min | 16 min 40 s | 22 min | 24 min | 38 min |
Both axes of the chart are stretched so that equal steps are equal numbers of stops. A film that needed no correction would follow the dotted line. Acros II very nearly does: its maker asks for nothing up to two minutes and half a stop beyond. Tabular-grain films from other makers sit between that and the curves above.
At dusk the light falls while the shutter is open. On any exposure longer than a minute, meter again half-way and add what was lost. More on this in the note on dusk.
Grey filters
| Stops | Density | Factor | 1/125 s becomes | 1/30 s becomes |
|---|---|---|---|---|
| 1 | 0.3 | 2× | 1/60 s | 1/15 s |
| 2 | 0.6 | 4× | 1/30 s | 1/8 s |
| 3 | 0.9 | 8× | 1/15 s | 1/4 s |
| 6 | 1.8 | 64× | 1/2 s | 2.1 s |
| 10 | 3.0 | 1 024× | 8.2 s | 34 s |
| 13 | 3.9 | 8 192× | 1 min 5 s | 4 min 35 s |
| 16 | 4.8 | 65 536× | 8 min 45 s | 36 min |
These are times on the dial. Anything over a second then goes through the table above. Ten stops and a red filter make thirteen; ten and six make sixteen, and at sixteen the strongest filter is patience. Coloured filters and their factors are in their own note.
Developer temperature
Times on the sheets are for 20 °C. In a house without heating in the darkroom the developer is rarely there. A fair rule is nine per cent less time for each degree warmer, nine per cent more for each degree colder.
| Developer at | Multiply by | 7 min 30 s becomes | 11 min becomes | 13 min becomes |
|---|---|---|---|---|
| 18 °C | 1.20 | 9 min | 13 min 15 s | 15 min 45 s |
| 19 °C | 1.10 | 8 min 15 s | 12 min | 14 min 15 s |
| 20 °C | 1.00 | 7 min 30 s | 11 min | 13 min |
| 21 °C | 0.91 | 6 min 45 s | 10 min | 11 min 45 s |
| 22 °C | 0.83 | 6 min 15 s | 9 min 15 s | 10 min 45 s |
| 23 °C | 0.76 | 5 min 45 s | 8 min 15 s | 9 min 45 s |
| 24 °C | 0.69 | 5 min 15 s | 7 min 30 s | 9 min |
Below 18 °C some developing agents slow down more than others and the rule stops being fair. Warm the bottle in a basin instead.
Kept elsewhere
- Exposure without a meter: Sunny 16 at the shore.
- Pinhole diameters and what they work out to: A pinhole on the pier.
- Starting times for three developers: The same roll in three developers.
- Push times: Pushing two stops on a grey morning.
- How many rolls a litre of fixer takes: Counting rolls.
- What the tide is good for: A tide table is an exposure tool.